22–24 Mar 2023
The Westin Zagreb, Croatia
Europe/Zagreb timezone

Numerical investigation of the seismic response of an unreinforced masonry residential building hit by the Zagreb earthquake in 2020

Not scheduled
20m
The Westin Zagreb, Croatia

The Westin Zagreb, Croatia

Kršnjavoga 1 10 000 Zagreb
Full paper - scientific Seismic Performance of Structures

Description

Despite the moderate intensity, the series of earthquakes in Zagreb (2020) caused significant social and economic impacts and damage to the built environment. The city of Zagreb has a moderate seismic hazard, but it is highly exposed (densely populated) and the built environment is quite vulnerable (age of structures, low maintenance, illegal construction, and numerous reconstructions). The greatest damage was sustained by masonry buildings for residential use in the historic downtown of Zagreb built in the late 19th and early 20th centuries. In addition to material deterioration, the transformations suffered by these buildings – often without being driven by anti-seismic standards - may increase their seismic vulnerability. Within this context, the main goal of the paper is to analyse the seismic response of an unreinforced masonry residential building selected to be representative of the existing historical masonry heritage in Zagreb downtown, built in the early twentieth century. The unreinforced masonry building (URM) has a rectangular floor plan and a 4-story elevation. Numerical investigations are carried out by using the equivalent frame method implemented in Tremuri software and by performing both nonlinear static and dynamic analyses. Although part of a residential block typical of the center of Zagreb, the structure has been considered as isolated. Indeed, the results reported in this paper must be intended as a preliminary step for the interesting future development of analyses addressed to account also the effects of interaction with adjacent buildings.

DOI https://doi.org/10.5592/CO/2CroCEE.2023.125

Primary authors

Ms Silvia Pinasco (Department of Civil, Environmental, and Chemical Engineering, University of Genoa, 16145 Genova, Italy) Prof. Marija Demšić (Department of Engineering Mechanics, Faculty of Civil Engineering, University of Zagreb,10000 Zagreb, Croatia) Prof. Marta Šavor Novak (Department of Engineering Mechanics, Faculty of Civil Engineering, University of Zagreb,10000 Zagreb, Croatia) Prof. Mario Uroš (Department of Engineering Mechanics, Faculty of Civil Engineering, University of Zagreb,10000 Zagreb, Croatia) Prof. Serena Cattari (Department of Civil, Environmental, and Chemical Engineering, University of Genoa, 16145 Genova, Italy) Prof. Sergio Lagomarsino (Department of Civil, Environmental, and Chemical Engineering, University of Genoa, 16145 Genova, Italy)

Presentation materials